page_banner

Troubleshooting and Solutions for Capacitor Energy Storage Spot Welding Machine

When using a capacitor energy storage spot welding machine, you may encounter some common problems. How should you deal with these issues when they arise? Here are some troubleshooting methods to help you navigate through these problems more effectively!

 

 

After powering on, the power indicator light on the control panel does not turn on.

Cause: Emergency stop switch is locked.

Solution: Unlock the switch.

After powering on, the energy storage indicator light on the panel does not turn on, and the abnormal indicator light is flashing. There is no charging voltage.

Cause: Charging fuse in the control box is blown.

Solution: Replace the fuse (380V/30A fuse).

After pressing the “on” switch, the welding machine automatically shuts off after a few seconds, and the fault persists after restarting.

Cause: 1. Charging thyristor breakdown. 2. Circuit board malfunction.

Solution: Replace.

The equipment’s voltage cannot reach the set value.

Cause: 1. Capacitor breakdown. 2. Discharge thyristor breakdown. 3. Protection diode breakdown.

Solution: Replace.

Sparking and splashing occur when the electrode contacts the workpiece.

Cause: Pre-press frequency is too short.

Solution: Increase the pre-press frequency.

Suzhou Agera Automation Equipment Co., Ltd. is engaged in the development of automated assembly, welding, testing equipment, and production lines, primarily used in the household appliances, automotive manufacturing, sheet metal, and 3C electronics industries. We offer customized welding machines and automated welding equipment, as well as assembly welding production lines and conveyor systems tailored to customer needs, providing suitable automation solutions to help companies transition from traditional to high-end production methods. If you are interested in our automation equipment and production lines, please feel free to contact us: leo@agerawelder.com


Post time: Feb-29-2024